Wago Control System In Large

Background   Large-scale sewage treatment4. Select outside except 750-812/814/815/816
plant distance between each reactor, while the750 controller + RS232/RS485 interface module
engineers to keep abreast of all aspects of motoras Master.
operation and valve switching, processing of theUpper HMI software: Upper HMI software support
targets before and after the sewage and otherMODBUSRTU required communication protocols,
conditions in order to make correspondingsuch as the Century Star, iFIX, Wanderware
adjustments in a timely manner. Now there is aInTouch, power control, configuration Wang ... ... ...
large-scale sewage treatment systems are allWAGO-I/O-SYSTEM the key product features:
kinds of problems. Option only instrument in the1. Easy to install modular structure, small size,
vicinity of each reactor show, so that staff cansave space, plug and play; WAGO spring cage
understand the present reactor data on varioustechnology, wiring is simple and reliable, vibration
indicators, but the engineer to understand allresistant, maintenance-free.
aspects of the situation takes some time, is not2. Users can use flexible arbitrary combinations of
conducive to engineer in time to makevarious functional modules together, and can
adjustments. Another option is to use industrial PCchange according to need bus adapters and other
and PLC control, so you can keep abreast of allfunctional modules, field bus to achieve agreement
aspects of the parameters, time to makefor the future with ease.
adjustments, but because every reactor control3. Complete functions to adapt to a variety of
room and the distance between the total, thefield bus communication and serial port
data collected from the control room to becommunication; function module varieties, fully
consumed the cost of relatively large number offunctional, contains a variety of voltage levels
analog bias that may arise, and problems with theapplied to the switch signal input / output module
rear access is not convenient. There are variousand analog input / output modules, relay modules,
responses on the part of a modular switches andcounter modules, power modules, interface
analog acquisition, but part of each responsemodules.
variable to be collected the number of different4. Design of each module on the economy less
types, module combination is not flexible enough,the number of channels, designed for the
and the module on the communication distanceeconomy to provide the conditions for fieldbus
has certain requirements for each communicationnode.
line between the need to connect the module, if5. Connect quickly and easily by bus, field bus
not part of the search module, resulting in theadapter input / output system quickly connected
whole system is not stable enough. Several of theto the PLC or PC.
above programs there are some problems need6. Protection up to IP65 protection class box to
to be some improvements.meet the development of industrial field bus
Note: PC is connected through the RS485 portsystems, such as the chemical industry, food
and WAGO-I/O-SYSTEM to achieve-to-manyindustry and other systems of protection
control.requirements, as well as metallurgy, chemical
The entire control system consists of WAGO-Iindustrial and mining enterprises harsh environment
O-SYSTEM, Century Star configuration software,of the scene, WAGO 750 Series offers protection
RS485 interface, the composition of industrial PC.with IP65 rating protective box.
WAGO-I/O-SYSTEM including on-site bus adapter,WAGO bus control system the flexibility to use
programmable fieldbus controller, 750 series dataPROFIBUS, DericeNet, CANopen,
input and output module, 750 series analog inputMODBUSEthernet, PROFINET and other programs.
and output modules, WAGO-I/O-PROCentury Star configuration software main
programming software, WAGO -I/O-CHECK bootfeatures:
and diagnostic tool. The above configuration1. Super graphics production functions: a gradual
according to specific requirements to make thecolor fill, bitmap from the screen capture point,
appropriate adjustment.three-dimensional pipe, etc., can image to visually
According to treatment need to capture allreflect the status of various equipment on site.
aspects of data and control the type and quantity2. Device configuration features: Driver using COM
of output, we have to identify each site WAGOcomponent technology to support the thousands
750 series bus configuration, and then by bus toof hardware devices at home and abroad, and
connect to the industrial PC on the RS485through Modem, RS232, RS485, RS422 MODBUS
Interface. Century Star configuration software viaprotocol based communication with other
MODBUS protocol and WAGO-I/O-SYSTEMsoftware, "Century Star" may call the shots stop,
connected to the sewage treatment to achievecan be used as slave.
the parameters of all aspects of the timely3. Advanced voice alarm technology: to create a
collection, and can realize the control of one toprecedent for configuration software, without
many. Century Star configuration software usingpre-recorded voice, you can let the computer for
the parameters of the monitoring, alarm andstandard Mandarin alarm, from the Chinese word
control functions.limit.
Field level: according to all aspects of treatment of4. The new configuration report function: the first
specific need to use 750 series adapter ortime, in industrial control software industry the
controller, communication interface RS232 orconcept of configuration reports, configuration
RS485, if the use of 750 series of programmablereports easy to use (similar to Excel), users can
controllers (750-812/814/815/816) , you caneasily get real-time reports and historical reports
control the distribution of tasks to complete.(such as class newspaper, daily, monthly, annual
Management level: the need for flexible control ofreports etc.).
the userIn addition, the powerful virtual machine
1. Select PC, or touch screen as the Master, usingtechnology, new management configuration
the built-in serial interface.concepts, integrated monitoring and surveillance
2. Select PLC as a Master, such as Schneider ... ..capabilities, historical data, more than make up the
3. Select WAGOIPC as the Master, can bepowerful functions are functions of the Century
connected to display data, and can be connectedStar configuration software with the.
through the Ethernet network of the upperFunction
management level.1.